Monday, June 11, 2012
PureAire’s O2 Monitor used in High Altitude Training Gains Recognition among Athletes
Since 2006 PureAire Monitoring Systems O2 Monitors have been used in Hypoxic High Altitude Training rooms. The training rooms are designed to lower the breathable oxygen using nitrogen, and the oxygen monitor is needed to maintain the environment. The technology used to lower the O2 level is used with a nitrogen generator. By lowering the breathable oxygen this creates a more strenuous workout for an athlete.
The generator is important as it dispenses on demand nitrogen at any given time lowering the oxygen levels. For typical training, the oxygen levels are near 15% with the balance of nitrogen. At 15% oxygen the altitude system tricks the body to believe it is training around 8,000 ft above sea level. The O2 deficiency monitor operation range is 0-25%. PureAire’s O2 deficiency monitor was defined as the best product to maintain these stable oxygen levels. Hypoxico Altitude Training Systems is the first to start selling and marketing a product like this.
PureAire’s oxygen deficiency monitor uses a zirconium oxide sensor. The monitor does not require maintenance or calibration. For these reasons, PureAire has been specified as the best fit for the altitude systems. The sensors life expectancy is 10+ years. In addition, the sensors are completely linear full scale of 0-25% giving an almost analyzer quality for the athletes.
Some clients which have been reported to use these altitude training systems are Prince Harry, Lance Armstrong, David Beckham, Cleveland Indians, Bear Grylls, and Michael Phelps. On 60 minutes Michael Phelps talks about using an altitude tent, but said he did not want to show this room to cameras. Many other athletes use altitude training as part of their exercise routines as well.
Altitude is characterized by the reduced partial pressure of oxygen. At a lower partial pressure, there is less oxygen in the air you breathe. It is this reduced oxygen content that stimulates the body to adapt and become more efficient in the uptake, transportation, and metabolism of oxygen. The HYPOXIC ALTITUDE TENT utilizes the same oxygen reduced air that one would find at high elevations. Our Hypoxic Generator continually separates out a portion of oxygen from ambient air before it is pumped into the enclosure. All other gases remain in the air, maintaining the atmospheric pressures of sea-level (or whatever altitude you are living at)1
The main O2 Monitor function which controls the desired training elevation, in the altitude room, is called hysteresis.
Hysteresis is similar to how an air conditioner keeps a desired temperature range in one’s home. For example, if 70f degrees are set on a home’s air conditioner, when the temperature begins to rise to 71f, the temperature control (hysteresis) turns on the air conditioning lowering the temp back down to 70f.
The PureAire O2 monitor has the same function. If the altitude room requires 15% oxygen, PureAire’s O2 monitors hysteresis will work similar to the air conditioner in a home. When the O2 levels rise to 15.5%, the O2 monitor will control the nitrogen generator lowering the O2 to the desired range of 15%.
PureAire is the only O2 monitor being used for altitude training systems currently and with the growing amount of athletes training, PureAire believes only the demand for these training systems will go up in the future.
Please contact PureAire toll free at 888-788-8050 with any questions or visit PureAire websites: http://www.MonitorOxygen.com, or http://www.PureAireMonitoring.com.
1) http://www.hypoxico.com/faq.shtml#4
Monday, April 2, 2012
Is your company using Nitrogen or other Cryogenic gases? Why PureAire Recommends an O2 Deficiency Monitor for Safety.
PureAire Monitoring Systems, Inc. focuses solely on safety in the workplace, and in laboratory environments. Oxygen deficiency monitors are used in areas using Nitrogen, Helium, Argon, and Carbon Dioxide. PureAire strongly recommends an oxygen deficiency monitor to be installed anywhere cryogenic gases are being stored.
The purpose of an oxygen monitor is to alert employees in the immediate area if there is a spill of nitrogen with audible alarm. The use of an O2 monitor creates a safer environment for employees and can alert local fire panels in a building as well. In New York, NY any area using more than 50 gallons of nitrogen the law states, it is mandatory for an oxygen monitor to be installed.
The largest problem with these specialty gases are, if a spill occurs there is no noticeable scent or effects. A nitrogen spill can create an oxygen deficient environment rapidly within seconds. For the time it takes the body to realize there is zero breathable oxygen, it is too late. A person will pass out from oxygen deprivation immediately. This is one of the most preventable incidents; simply install an oxygen deficiency monitor for safety.
Consider an argument for medicine. If one was to travel to the Amazon in South America, where malaria is common, being unaccustomed to the jungle, wouldn’t it be wise to take malaria pills? What if you have a family history of diabetes? As a family member you may consider taking any necessary precautions to possibly eliminate the concern of diabetes. Maybe by being more physically active, or having a healthier diet, this may delay or stop the onset of diabetes.
An oxygen monitor is also similar to a Fire detector in your home or office. You never expect to have a fire, but a fire detector is installed for safety as a precaution.
PureAire feels the oxygen monitor is the preventative medicine. Scientists and researchers will always continue to use nitrogen for their experiments. Doctors will continue to use helium to cool the large magnets used for images in the MRI scanner. Carbon dioxide will still be used for all beverage dispensing systems at fast food chains. The one factor people cannot eliminate is the use of cryogenic gases used in everyday life. The only known safety, and scientifically proven device is the oxygen deficiency monitor.
The rooms dimensions, a size of the cylinders, the quantity of the cylinders, the types of cryogenic gas being used, whether the gas is being piped into a room, and height of the ceiling all play a role on where, and how many monitors are required. PureAire often gets the question, where do we place the oxygen monitor? How many O2 monitors should we use?
A few simple tips can help save a life. Helium is lighter than air, so it is recommended to mount the monitor closer to the ceiling, whereas nitrogen/argon is heavier than air, so mounting the monitor closer to the ground would make sense. Carbon dioxide is also heavier than air settling to the ground.
PureAire manufactures oxygen deficiency monitors for many different areas. In all cases PureAire use an oxygen deficiency monitor using a 10+ year sensor. PureAire can be contacted at 1-888-788-8050, http://www.MonitorOxygen.com, and http://www.PureAireMonitoring.com.
Wednesday, March 21, 2012
Are you using the right monitor for CO2?
Carbon dioxide, (CO2) detectors are commonly used to protect workers from leaks in fast food establishments and restaurants. The OSHA, ACGIH and NIOSH CO2 threshold limit value for 8 hours, (TLV) is 5,000 PPM, and the ACGIH and NIOSH short-term exposure level, (STEL) is 30,000 PPM. Although these agencies established worker exposure levels, they also all state:
“ The health effects of Carbon dioxide is a simple asphyxiant (HE17).” 1
Workers have been seriously injured due to exposure to oxygen deficiency in fast food facilities due to faulty or non-responsive CO2 monitors.
It is fact that a carbon dioxide leak from a faulty beverage dispensing system in a work environment displaces oxygen. The real health hazard is not from exposure to CO2, it’s from a lack of oxygen. “Carbon dioxide gas is an asphyxiant with effects due to lack of oxygen.” 2
“Inhaling large concentrations causes rapid circulatory insufficiency leading to coma and death. Asphyxiation is likely to occur before the effects of carbon dioxide overexposure.” 3
Virtually every publication and article written about CO2 exposure indicate that the real risk to life and health is from a lack of oxygen. CO2 monitors can not detect oxygen deficiency so why do fast food establishments and restaurants rely on them for protecting their workers when the real risks are from a lack of oxygen?
PureAire manufactures an Oxygen monitor designed to instantly detect the smallest changes in oxygen levels as a result of a CO2 leak. The earth is a wonderful source of calibrated oxygen and unlike CO2 monitors that read 0% even when the oxygen level is lower, PureAire reads continuously monitors the actual oxygen level 24-7. It’s designed to instantly alarm to hazardous levels caused by a CO2 leak.
PureAire’s oxygen monitor uses a 10+ year no maintenance no calibration sensor. All monitoring system functions are 100% supervised and fault protected. Workers are always assured of continuous protection from oxygen deficient environments from leaking CO2 and alerted in the event of a failure. In addition the oxygen monitor has built-in alarm relays for controlling automated ventilation fans or connecting to standard fire alarm panels.
It’s proven that a CO2 leak causes asphyxiation well before the effects of overexposure, and CO2 monitors can not be used to detect lower oxygen levels, then it’s clear that companies are using the wrong monitor!
A major producer of CO2 gas actually uses PureAire oxygen monitors in their gas processing plants because of their concern of lower oxygen levels due to CO2 releases. We agree with them.
Please contact PureAire toll free at 888-788-8050 for more information or visit PureAire websites, www.MonitorOxygen.com or www.PureAireMonitoring.com.
1. United States Department of Labor, Occupational Safety & Health Organization, CO2, Chemical Sampling Information, Carbon dioxide. Revision date 9/20/2001
2. Praxair Material Safety Data Sheet, Product: Carbon Dioxide P-4574-J Date: July 2007
3. BOC Gases, Material Safety Data Sheet, MSDS: G-8 Revised: 6/7/96
Labels:
co2 monitor,
confined space monitor,
O2 Monitor
Monday, February 13, 2012
The Beverage Industries Incorrect Way of Monitoring for CO2 leaks: Why CO2 Monitor is the Wrong Solution. Hear why PureAire’s Oxygen Monitor is a Bett
Carbon Dioxide (CO2) is the primary compressed gas used for beverages at major fast food chains. This gas is also used in restaurants, gas stations, and grocery stores. When CO2 leaks into a confined space or basement, this creates a very unsafe workplace for employees by lowering the breathable oxygen. History seems to repeat itself all too often while dealing with CO2. Due to the CO2 leaks several times a year, employees have become sick and in worst cast scenarios, have died from asphyxiation.
Below is a link to the Phoenix Fire Department video on a CO2 leak at a fast food chain. Two Fire men were overcome by CO2 in a basement of a chain. http://nfpa.typepad.com/fireservicetoday/2011/10/lesson-learned-co2-leak-at-mcdonalds-harmful-to-employee-and-responders.html
It has become a standard in the industry to use a CO2 monitor; this is outdated and should be replaced with an Oxygen Monitor. CO2 Leaks are a Oxygen deficiency problem as CO2 displaces oxygen creating an unsafe workplace. PureAire is a leader for oxygen monitors in the workplace for safety. PureAire makes an Oxygen monitor with a 10+ year sensor without maintenance, and calibration. This is very important advantage over the CO2 monitors being used.
The CO2 monitors installed in fast food chains are the wrong approach. The CO2 monitors used are low cost, and can do more harm than good. A gas monitor is a scientific piece of equipment. The technology used in the CO2 monitor requires maintenance, calibration, and monthly testing. Without oversight, the monitors will begin to fail or become unresponsive. The lacks of attention to the current CO2 Monitors are a common problem amongst the fast food employees.
Employees at fast food chains are not trained on compressed CO2 typically. Employees are the first people to work with CO2, and in most cases are required to change CO2 gas in a basement or confined space. What if there is a leak? What if the CO2 monitor is non functional? This result can be catastrophic.
PureAire believes strongly the answer is not a CO2 monitor, but an Oxygen Monitor. CO2 will always displace oxygen and will lower the breathable oxygen levels. PureAire’s Oxygen Monitor is unlike any other, using a 10 + year sensor which is 24/7 supervised. The O2 Monitor is safer and much more reliable. Using PureAire’s O2 Monitor will eliminate the concerns about CO2 spills. If there is a leak of Oxygen, the O2 Monitors alarm will sound alerting employees. PureAire‘s 24/7 supervision will ensure the monitor is functioning properly, and responsive when it is needed most.
PureAire’s knows you cannot always count on an employee’s knowledge of the CO2 risks, the signs of CO2 exposure, and the dangers of CO2. This is why PureAire’s monitor is the best choice. The monitor can also be configured with an exhaust fan, further enhancing the safety with complete automation.
Please contact PureAire if you have anymore questions at 1-888-788-8050. PureAire websites are www.MonitorOxygen.com, or www.PureAireMonitoring.com.
The Beverage Industries Incorrect Way of Monitoring for CO2 leaks: Why CO2 Monitor is the Wrong Solution. Hear why PureAire’s Oxygen Monitor is a Bett
Carbon Dioxide (CO2) is the primary compressed gas used for beverages at major fast food chains. This gas is also used in restaurants, gas stations, and grocery stores. When CO2 leaks into a confined space or basement, this creates a very unsafe workplace for employees by lowering the breathable oxygen. History seems to repeat itself all too often while dealing with CO2. Due to the CO2 leaks several times a year, employees have become sick and in worst cast scenarios, have died from asphyxiation.
Below is a link to the Phoenix Fire Department video on a CO2 leak at a fast food chain. Two Fire men were overcome by CO2 in a basement of a chain. http://nfpa.typepad.com/fireservicetoday/2011/10/lesson-learned-co2-leak-at-mcdonalds-harmful-to-employee-and-responders.html
It has become a standard in the industry to use a CO2 monitor; this is outdated and should be replaced with an Oxygen Monitor. CO2 Leaks are a Oxygen deficiency problem as CO2 displaces oxygen creating an unsafe workplace. PureAire is a leader for oxygen monitors in the workplace for safety. PureAire makes an Oxygen monitor with a 10+ year sensor without maintenance, and calibration. This is very important advantage over the CO2 monitors being used.
The CO2 monitors installed in fast food chains are the wrong approach. The CO2 monitors used are low cost, and can do more harm than good. A gas monitor is a scientific piece of equipment. The technology used in the CO2 monitor requires maintenance, calibration, and monthly testing. Without oversight, the monitors will begin to fail or become unresponsive. The lacks of attention to the current CO2 Monitors are a common problem amongst the fast food employees.
Employees at fast food chains are not trained on compressed CO2 typically. Employees are the first people to work with CO2, and in most cases are required to change CO2 gas in a basement or confined space. What if there is a leak? What if the CO2 monitor is non functional? This result can be catastrophic.
PureAire believes strongly the answer is not a CO2 monitor, but an Oxygen Monitor. CO2 will always displace oxygen and will lower the breathable oxygen levels. PureAire’s Oxygen Monitor is unlike any other, using a 10 + year sensor which is 24/7 supervised. The O2 Monitor is safer and much more http://www.blogger.com/img/blank.gifreliable. Using PureAire’s O2 Monitor will eliminate the concerns about CO2 spills. If there is a leak of Oxygen, the O2 Monitors alarm will sound alerting employees. PureAire‘s 24/7 supervision will ensure the monitor is functioning properly, and responsive when it is needed most.
PureAire’s knows you cannot always count on an employee’s knowledge of the CO2 risks, the signs of CO2 exposure, and the dangers of CO2. This is why PureAire’s monitor is the best choice. The monitor can also be configured with an exhaust fan, further enhancing the safety with complete automation.
Please contact PureAire if you have anymore questions at 1-888-788-8050. PureAire websites are www.MonitorOxygen.com, or .
Below is a link to the Phoenix Fire Department video on a CO2 leak at a fast food chain. Two Fire men were overcome by CO2 in a basement of a chain. http://nfpa.typepad.com/fireservicetoday/2011/10/lesson-learned-co2-leak-at-mcdonalds-harmful-to-employee-and-responders.html
It has become a standard in the industry to use a CO2 monitor; this is outdated and should be replaced with an Oxygen Monitor. CO2 Leaks are a Oxygen deficiency problem as CO2 displaces oxygen creating an unsafe workplace. PureAire is a leader for oxygen monitors in the workplace for safety. PureAire makes an Oxygen monitor with a 10+ year sensor without maintenance, and calibration. This is very important advantage over the CO2 monitors being used.
The CO2 monitors installed in fast food chains are the wrong approach. The CO2 monitors used are low cost, and can do more harm than good. A gas monitor is a scientific piece of equipment. The technology used in the CO2 monitor requires maintenance, calibration, and monthly testing. Without oversight, the monitors will begin to fail or become unresponsive. The lacks of attention to the current CO2 Monitors are a common problem amongst the fast food employees.
Employees at fast food chains are not trained on compressed CO2 typically. Employees are the first people to work with CO2, and in most cases are required to change CO2 gas in a basement or confined space. What if there is a leak? What if the CO2 monitor is non functional? This result can be catastrophic.
PureAire believes strongly the answer is not a CO2 monitor, but an Oxygen Monitor. CO2 will always displace oxygen and will lower the breathable oxygen levels. PureAire’s Oxygen Monitor is unlike any other, using a 10 + year sensor which is 24/7 supervised. The O2 Monitor is safer and much more http://www.blogger.com/img/blank.gifreliable. Using PureAire’s O2 Monitor will eliminate the concerns about CO2 spills. If there is a leak of Oxygen, the O2 Monitors alarm will sound alerting employees. PureAire‘s 24/7 supervision will ensure the monitor is functioning properly, and responsive when it is needed most.
PureAire’s knows you cannot always count on an employee’s knowledge of the CO2 risks, the signs of CO2 exposure, and the dangers of CO2. This is why PureAire’s monitor is the best choice. The monitor can also be configured with an exhaust fan, further enhancing the safety with complete automation.
Please contact PureAire if you have anymore questions at 1-888-788-8050. PureAire websites are www.MonitorOxygen.com, or .
Why the use of a CO2 monitor may not be the best solution for protecting workers against leaks from beverage dispensing systems in the fast food ind
Carbon Dioxide (CO2) is the primary compressed gas used forhttp://www.blogger.com/img/blank.gif dispensing beverages at fast food chains. This gas is also used in restaurants, gas stations, and grocery stores. When CO2 leaks into a confined space or basement, it creates a very unsafe environment for employees because it lowers the concentration of breathable oxygen. History seems to repeat itself all too often while dealing with CO2 leaks from dispensing systems. Due to numerous CO2 leaks in the workplace, lower oxygen levels have resulted in employees becoming sick or dying, from asphyxiation.
Below is a link to the Phoenix Fire Department video on a CO2 leak at a fast food chain. An employee and two firemen were overcome by a lack of oxygen due to a CO2 leak in the basement of a restaurant. http://nfpa.typepad.com/fireservicetoday/2011/10/lesson-learned-co2-leak-at-mcdonalds-harmful-to-employee-and-responders.html
The use of a CO2 monitor is accepted as a standard method in the industry, however since a leak actually creates an oxygen deficient environment; the use of an Oxygen monitor would provide better protection. CO2 displaces oxygen.
PureAire is a leading supplier of oxygen monitors for protecting people in the workplace. Its Oxygen monitor uses a proprietary non depleting sensor with a 10+ year life. The monitor requires no maintenance or the need for routine calibration; a very important advantage over the CO2 monitors being used.
The use of a CO2 monitor to protect people against oxygen deficiency in fast food chains can be the wrong approach since it’s the lack of breathable oxygen that is causing injury. Companies however are attracted to the low cost of CO2 monitors and since there is no regulation to use oxygen monitors, there is no incentive to provide better protection. Virtually every response to a CO2 leak resulted in a conclusion that workers were overcome by a lack of oxygen, which cannot be detected using a CO2 monitor.
PureAire believes that the use of a CO2 monitor alone cannot provide adequate protection to a leak. When storing large cylinders of liquid CO2 in confined spaces, complete protection should include an oxygen deficiency monitor.
Most users of CO2 dispensing systems do not have trained technical staff to maintain a monitoring system. All monitoring and system functions on PureAire’s oxygen monitor are 100% supervised and fault protected. Employees are always assured of continuous protection and are alerted to any failures.
The earth is a wonder source of calibrated oxygen and under normal ambient conditions of 20.9%, the monitor is continuously exposed to calibrated gas. CO2 monitors read zero when not exposed, and therefore require routine calibration to insure they’re working. This is not required for PureAire’s oxygen monitor.
In addition to its long life, no maintenance sensor, the oxygen monitor has built-in alarm relays for controlling ventilation fans or connecting to standard fire alarm panels. A major producer of CO2 gas actually uses PureAire oxygen monitors in their gas processing plant because of their concern of lower oxygen levels due to a CO2 release. We agree with them.
Please contact PureAire toll free at 888-788-8050 with any questions or visit PureAire websites, www.MonitorOxygen.com, or www.PureAireMonitoring.com.
Thursday, December 8, 2011
PureAire’s Methyl Bromide Monitor Gains Exposure from the Department of Pesticide Regulation
There has been an increased awareness for methyl bromide safety in the past few months. Over a year ago two employees at a cold storage warehouse got physically ill from high levels of methyl bromide. The Ch3br gas was off gassing from the products causing a higher than safe level for the employees. Commodities being shipped from overseas must be fumigated in ports, or warehouses upon arrival to kill off any pests. California DPR has announced PureAire can be used as a real time Methyl Bromide Gas Monitor for safety in the workplace.
PureAire is the only EPA compliant Ch3Br monitor for fumigation safety. The Aircheck monitor is in real time, monitoring 24/7, and capable of detecting low 0.3 parts-per-million. PureAire's president, Al Carrino saw a demand for a low methyl bromide monitor. From his complex understanding of Methyl Bromide, he was determined to get the EPA, DPR, and the State of California to recognize PureAire's monitor.
Effective June 25, 2008, the Department of Pesticide Regulation of the California EPA has added a real time remote sensor monitor for the detection of Ch3Br by PureAire Monitoring Systems, in addition to colorimetric detector tubes. The PureAire Air Check Advantage Continuous Methyl Bromide Monitor can now be used to monitor enclosed areas, including warehouse fumigation clearing and commodity fumigation clearing1. Some commodities include grapes, walnuts, strawberries, and asparagus.
The PureAire Air Check Advantage Monitoring System detects and measures methyl bromide in a range of 0 to 10 ppm. Installation of the Ch3Br monitor is simple. For warehouses storing commodities, the Ch3Br monitor should wall mounted at eye level or for easy access. The monitor has a sample inlet and sample outlet port. The monitor can sample directly from the monitors inlet, or a sample tube can be installed increasing the sampling distance to 100 ft.
The Ch3Br monitor is designed for fumigation clearing chambers and storage areas. The monitor is ideal for providing worker protection at orchards, for growers, international airports, and seaports where commodities are fumigated before shipping.
Functions include:
1. 0.3 PPM detectable limit, 0-10 PPM sensor range
2. A local back-light digital display
3. 4-20 mA signal for controller or fire panels
4. 2 User selectable relays or alarms
5. Capable of turning on/off horns and strobes
6. Test and reset modes
7. Sampling length of 100ft
This monitor can replace the use of colorimetric tubes, and provide employees with a "Real Time," monitor. If you have anymore questions please call 1-888-788-8050. U.S. Website: http://www.PureAireMonitoring.com.
Subscribe to: